Surface Protection

PRODUCT DETAILS
3’X50′ = 150 SF
3’X100′ = 300 SF

Product Care And Installation

  • Protect against direct solar radiation; be sure to cover the entire area to avoid character change.
  • Turn off floor heat prior to applying protection.
  • Ensure all areas are dry prior to laying.
  • Once the product is applied, it cannot endure pressure of more than 220 lbs for more than 24 hours.
  • For various site conditions, a test should be done prior to applying to confirm the surface is cured.
  • Wait at least 72 hours after the final coat has been applied before covering.
  • Do not use on surfaces that have been treated with any solvent-based products before they have been properly cured.
  • Not recommended on cement or concrete surfaces.
  • Recommended room temperature 50°F – 77°F.
  • Allowable room humidity 50% – 60%.
  • Should be laid down with a 4” overlap on each side.
  • Lift protection periodically and reapply.
  • Prepare the surface, making sure it is free of dust and debris.
  • Roll out to the desired size and cut with a utility knife/scissors away from the surface.
  • Smooth out over the surface, applying pressure with hands.
  • When removing the product, if there is any residue/glue on the surface, use a neutral pH soap with warm water to remove it.


Disclaimer

The technical data provided as well as instructions are based on our experiences and best knowledge.

Bleu Tek does not represent or guarantee certain properties, and it is the sole responsibility of the USER to ensure the conditions are appropriate for use. Bleu Tek does not guarantee or warranty against any damage that may be caused on top or underneath surface protection. It is solely the responsibility of the user to do their own due diligence and testing on all conditions prior to any coverings to ensure no damage is incurred.

Technical Data Table
Technical Data
Property Value Norm
Material PTE fibers (recycled fibers) needled
Form of reinforcement Top breathable PP film
Underside
Weight 0.033 lbs per sq.ft
160g/m² (+/-10%)
DIN EN 29073-1
Thickness 2.5 - 2.8mm DIN EN ISO 9073-2
Thickness with 0.5kpa load (approx. 50g/cm²) 1.52mm (+/-10%) DIN EN ISO 9073-2
Dimensions 36" x 50' = 150 SF
36" x 100' = 300 SF
Maximum ling 120N/5cm (+/-20%) DIN EN 29073-3
Maximum transverse tensile strength 115N/5cm (+/-20%) DIN EN 29073-3
Maximum longitudinal extension 80% (+/-20%) DIN EN 29073-3
Maximum transverse extension 90% (+/-20%) DIN EN 29073-3
Water vapor permeability of the film 25g/m²/24h EN 12572 climate C
RH50/100 @ 23°C, WetCup
Width of the film 1M
Water depth of the film >6m DIN 53886 (With support grid)